Article

Emerging Strategies for Stroke Prevention in Atrial Fibrillation

Register or Login to View PDF Permissions
Permissions× For commercial reprint enquiries please contact Springer Healthcare: ReprintsWarehouse@springernature.com.

For permissions and non-commercial reprint enquiries, please visit Copyright.com to start a request.

For author reprints, please email rob.barclay@radcliffe-group.com.
Average (ratings)
No ratings
Your rating

Abstract

Atrial fibrillation (AF) is a common cause of stroke. In the US nearly 800,000 people suffer stroke each year and about 130,000 die as a result. Stroke care accounts for an estimated US$34 billion in health care expenditures in the US each year. Among all strokes, AF is the cause in 15–20 % of cases. The incidence of AF in the US has grown steadily over time to a current estimate of 6.1 million with the condition. With the anticipated growth in the worldwide AF population, the need for effective new therapeutic strategies for stroke prevention is clear.

Disclosure:The authors have no conflicts of interest to declare

Received:

Accepted:

Correspondence Details: Mitchell N Faddis, Director of Clinical Cardiac Electrophysiology, Associate Professor of Medicine, Washington University School of Medicine, 660 S. Euclid Ave, St Louis, MO 63110, USA. E: mfaddis@dom.wustl.edu

Copyright Statement:

The copyright in this work belongs to Radcliffe Medical Media. Only articles clearly marked with the CC BY-NC logo are published with the Creative Commons by Attribution Licence. The CC BY-NC option was not available for Radcliffe journals before 1 January 2019. Articles marked ‘Open Access’ but not marked ‘CC BY-NC’ are made freely accessible at the time of publication but are subject to standard copyright law regarding reproduction and distribution. Permission is required for reuse of this content.

It is presumed that the pathogenesis of stroke in atrial fibrillation (AF) patients is due to embolization of thrombus from the left atrium. Within the left atrium, the left atrial appendage is the predominant site of thrombus formation. In a study of 233 patients with new onset AF of greater than 48 hours in duration who were not anticoagulated, left atrial appendage thrombus was present in 15 % of patients.1 Among patients with a recent embolic stroke, the association of atrial fibrillation and left atrial appendage thrombus is present in more than 20 % of patients.2 In patients with documented left atrial appendage thrombus and AF discovered during transesophogeal echochardiograhy (TEE), the subsequent incidence of transient ischaemic attack (TIA) is nearly 10-fold higher than those without thrombus.3

Systemic anticoagulation with warfarin has been shown to reduce the incidence of stroke in AF patients by about two thirds.4 In spite of the proven efficacy of warfarin therapy for stroke prevention, the effective and safe use of this agent has proved challenging. In particular, frequent blood tests, dietary effects, and pharmacologic interactions with other therapeutic agents limits effective use of this agent. The requirement for tight control of the intensity of anticoagulant effect of warfarin has resulted in frequent occurrences of under- and overdosing. Despite intention-to-treat with warfarin, 50 % of patients who experience a stroke are found to have subtherapeutic anticoagulation.4 Supratherapeutic anticoagulation raises the risk of severe bleeding episodes including intracranial hemorrhage.5 Among patients prescribed warfarin, one in four discontinue the medication within the first year of use.6

Recently, the introduction of a series of novel oral anticoagulants (NOACs) has provided therapeutic alternatives to warfarin in patients with preserved renal function. In a meta-analysis of the major clinical trials of these agents including the direct thrombin inhibitor dabigatran and the factor Xa inhibitors apixoban, rivaroxaban and edoxaban, the incidence of stroke or systemic embolic events was reduced by 19 % relative to patients treated with warfarin.7 Although the risk reduction for ischemic stroke was similar to warfarin in the meta-analysis, the incidence of intracranial hemorrhage (a separate cause of stroke) was reduced by 52 %. In spite of the enhanced stroke prevention efficacy associated with the NOACs, a 25 % increase in gastrointestinal bleeding was observed with these agents.

A new standard risk calculation has now been widely adopted because of bleeding risks inherent in systemic oral anticoagulation. This has helped guide the decision based on quantification of the risk of thromboembolic events in patients with non-rheumatic AF. Known by the acronym CHADS2-VASc (C = congestive heart failure; H = hypertension; A = age; D = diabetes mellitus; S2 = Stroke and female sex; Vasc = vascular disease), this risk calculation assigns points for the known stroke risk factors in non-rheumatic AF made up by female sex, a history of congestive heart failure, hypertension, age >65 years, age >75 years, diabetes mellitus, vascular disease, and two points for a prior history of stroke. In both men or women with one additional risk factor, oral anticoagulation is recommended. The effect of this new risk calculation scheme, relative to the older CHADS2 system, is to include a larger portion of patients with AF in the recommendation for oral anticoagulant. The predicted effect of these recommendations together with the new oral anticoagulants should be more comprehensive stroke protection in the AF patient population. Despite this, many patients have contraindications to oral anticoagulation due to fall or bleeding risks and proven alternative stroke prevention strategies are needed.

Rhythm Control

There have been several randomized trials comparing rate versus rhythm control in patients with AF. These trials have demonstrated similar rates of death or embolism regardless of the strategy.9–13 Of these, the A Comparison of Rate Control and Rhythm Control in Patients with Atrial Fibrillation (AFFIRM) trial was the largest, randomizing 4,060 patients with recurrent AF to rate control (using beta blockers, calcium channel blockers or digoxin) and anticoagulation with warfarin compared to the most effective antiarrhythmic drug. All patients were initially anticoagulated, but those in the rhythm control group who maintained sinus rhythm for at least four, but preferably 12, consecutive weeks could be withdrawn from warfarin. In the rhythm control arm the most frequently used antiarrhythmics were amiodarone (38 %) and sotalol (31 %).

By the end of the 3.5 years of follow-up, 63 % had been prescribed amiodarone at least once. Patients initially assigned to rhythm control crossed over to the rate control group in 17 % of patients at one year and 38 % of patients at 5 years. This was mainly due to a failure to maintain sinus rhythm or intolerance to the antiarrhythmic medications. After the 3.5 years of follow-up the rate control arm had a trend toward a significant decrease in all-cause mortality (21.3 % versus 23.8 %; HR 0.87; 95 % CI [0.75–1.01]). There was no statistical difference between the groups in cardiac death, arrhythmic death or deaths due to ischemic or hemorrhagic stroke.9 However, groups without a history of heart failure and those aged >65 years or older had a significant reduction in mortality with rate control.14 There was a higher rate of stroke among those patients who had discontinued warfarin, suggesting that anticoagulation should be continued even if a rhythm control strategy is pursued. This is in part due to a high rate of recurrence of AF, even if asymptomatic.9

Restoration of sinus rhythm can be a valuable goal for many patients with symptoms or hemodynamic consequences from AF. Antiarrhythmic medications have potential side effects, can be proarrhythmic and can increase mortality.15 The 2014 AHA/ACC/HRS guidelines regarding the management of patients with AF suggest that catheter ablation is reasonable for patients who have failed at least one antiarrhythmic medication.16 Potential procedural risks of ablation, however, must be weighed carefully against risks of long-term use of antiarrhythmic drugs.

In a multicenter Italian registry, major complications occurred in 4 % of patients (2.2 % vascular access, 0.5 % cardiac tamponade, 0.6 % pericarditis, 0.2 % transient ischemic attacks, 0.2 % stroke and 0.1 % had phrenic nerve paralysis).17 Complications such as pulmonary vein stenosis or atrial-esophageal fistulae happened rarely but were probably under recognised if they occurred late. Despite the evolution of AF ablation over the past several years, recurrence rates are still high enough to warrant continuation of long-term anticoagulation. A systematic review of six trials suggested recurrence of AF after one year occurred in 20–40 % of patients after catheter ablation and in greater than 70 % of patients on antiarrhythmic drugs.18 Hence, rhythm control with antiarrhythmic medications or catheter ablation is useful for reducing symptoms or hemodynamic consequences of AF but should not be used as a means of reducing thromboembolic risk.

Left Atrial Appendage Occlusion

The left atrial appendage (LAA) has been shown to be the location of thrombus formation 91 % of the time in patients with non-valvular AF.19 The structure of the LAA varies and consists of two lobes in 54 % of the population and three lobes in 23 % of the population.20 There have also been several studies to show the LAA has important functions in the release of atrial and brain natriuretic peptides, and loss of this may have adverse consequences on volume status after LAA occlusion.21,22 Up to one-third of patients who would benefit from anticoagulation based on their CHADS2 score cannot take warfarin due to various contraindications.23 Hence, there has been increasing interest in physically occluding the LAA to decrease risk of thromboembolic events associated with AF.

Occlusion of the LAA was first achieved surgically in 1949 in patients with rheumatic AF. The surgical procedure has evolved over the past several decades in its methods and efficacy, and there has been increasing interest recently in devising less invasive methods to occlude the LAA. One of the first percutaneous methods to occlude the LAA was the Thorascopic Extracadiac Obliteration of the Left Atrial Appendage for Stroke Risk Reduction in Atrial Fibrillation (LAPTONI) procedure, which used a left lateral thoracotomy approach to ensnare the LAA to the base from the epicardial aspect.24 Since then, there have been several percutaneous methods developed to occlude the LAA from either the epicardial on endocardial approaches.

The LARIAT® device (SentreHeart) was created as a catheter-based method to ensnare the LAA from the epicardial aspect. An endorcardial balloon catheter with a magnetic tip is placed via transseptal access into the LAA. With pericardial access, a separate magnetic tipped catheter is advanced to the epicardial aspect of the LAA to meet at the appendiceal tip with the endocardial magnetic balloon. The LAA ostium is identified with balloon inflation of the endocardial catheter, and a pre-tied suture is advanced from the epicardial aspect over the magnetic guidewire rail to the base of the LAA. The suture is tightened and the endocardial balloon is deflated and removed. Through this technique there is no permanent endocardial structure, which limits risk of infection or device embolization.

Procedural complications can occur with access of the dry pericardium, transseptal access and perforation or laceration of the LAA. Miller et al. published a cohort of 41 patients who had undergone LARIAT. The acute success of the procedure, defined as complete occlusion of the LAA with <1 mm LAA leak on intraprocedural TEE, is approximately 93 %.25 Limitations to successful closure included large LAA size, numerous lobes, unfavorable LAA anatomy or pericardial adhesions. Long-term success has been variable and residual LAA leak seen on a CT scan or TEE at 3 months was seen in 24 % of patients.25

A larger multicenter study from the US Transcatheter LAA Consortium showed successful suture deployment in 94 % of patients.26 Major complications including death, myocardial infarction, stroke, or cardiac surgery occurred in 9.7 % of patients. Other complications included significant pericardial effusion (10.4 %) and major bleeding (9.1 %). At follow-up TEE 1–3 months post-procedure, there was a high incidence of residual leak (20 %).26 The major advantage of LARIAT is that anticoagulation is not required after complete occlusion of the LAA. However, due to the high incidence of residual leak afterwards, many centres will continue anticoagulation for at least 1–3 months post-procedure if there is no residual leak seen on follow-up TEE.27,28 Randomized, controlled trials are required to further evaluate the long-term safety and efficacy of the LARIAT device as an alternative to anticoagulation.

Several endocardial LAA occlusion devices have also been developed. The most notable of these is the WATCHMAN™ device (Boston Scientific). This parachute-shaped device is a self-expanding nitinol cage with fixation anchors and a membrane made of polytetrafluoroethylene. It is available in various sizes (20 mm, 21 mm, 24 mm, 27 mm and 33 mm) and should be sized 10–20 % larger than the LAA. A sheath is placed via transseptal access into the LAA over a pigtail catheter. The device is then advanced through this sheath and sized and placed in the LAA ostium under TEE and fluoroscopic guidance. This device requires that patients are anticoagulated with warfarin for at least 45 days post-procedure.

The WATCHMAN Left Atrial Appendage System for Embolic PROTECTion in Patients with Atrial Fibrillation (PROTECT) AF study was the first randomized, controlled trial comparing a LAA occlusion device versus warfarin.29 This was a non-inferiority study for 707 patients with non-valvular AF who were eligible for anticoagulation with warfarin. The patients were randomized in a 2:1 ratio for WATCHMAN or anticoagulation with a follow-up of 18 months. The device was successfully deployed in 91 % of patients. If follow-up TEE demonstrated residual flow ≤3 mm around the device, warfarin was discontinued in 86 % of patients at 45 days and 92 % of patients at 6 months. The primary efficacy endpoint was a composite of stroke, cardiovascular death and systemic embolism occurred in 3.0 per 100 patient-years in the device group and 4.9 per 100 patient-years in the warfarin group (RR = 0.62; 95 % CI [0.35–1.25]). The probability for non-inferiority of the intervention group was more than 99.9 %. The primary safety endpoint included major bleeding, pericardial effusion, and device embolization, which occurred more frequently in the device group than in the control group (7.4 versus 4.4 per 100 patient-years, RR = 1.69, 95 % CI [1.01–3.19]). There were five procedural-related ischemic strokes, 22 pericardial effusions and three device embolizations.11 Due to the higher rate of the primary safety endpoint in the WATCHMAN group and the lack of long-term follow-up data, the US Food and Drug Administration requested a second randomized trial prior to device approval.

The Prospective Randomized Evaluation of the WATCHMAN Left Atrial Appendage Closure Device in Patients with Atrial Fibrillation Versus Long-Term Warfarin Therapy (PREVAIL) study was designed to validate the initial results of PROTECT AF.30 This trial randomized 407 patients with a mean CHADS2 score of 2.6 in a 2:1 fashion to device versus warfarin. At 18 months, the rate of the first co-primary efficacy endpoint (composite of stroke, systemic embolism and cardiovascular/unexplained death) was 0.064 in the device group and 0.063 in the control group with a RR of 1.07 with an upper bound of 1.89, which was higher than the prespecified criterion of 1.75 for non-inferiority (CI 95 %). Although this trial did not achieve non-inferiority for this endpoint, it did achieve non-inferiority for the second co-primary efficacy endpoint (stroke or systemic embolism >7 days post-randomization) at a rate of 0.0253 in the device group compared to 0.0200 in the control group (95 % credible interval (CrI) -0.0190–0.0273). Early safety events occurred in 2.2 % of the patients in the WATCHMAN arm, significantly lower than in PROTECT AF, achieving the pre-specified performance goal. A significant improvement in implant success rate of 95.1 % was noted compared to 90.9 % in the PROTECT AF trial.

The Continued Access Protocol (CAP) registry was designed to gain further efficacy and safety data in a non-randomized fashion in patients undergoing WATCHMAN implantation.31 Combining longer- term data from PROTECT AF and CAP, there was a significant decrease in procedure or device-related safety events. The rate of serious pericardial effusion decreased from 5.0 % in PROTECT AF to 2.2 % in CAP (p=0.019) and periprocedural stroke decreased from 0.9 % to 0 % (p=0.039).31 There was also a reduction in safety events noted from the first half of the PROTECT AF patients compared to the second half of the study. This signifies a reduction of safety events with improved operator experience.31 Newer data from the PROTECT AF study with a follow-up of 3.8 years was published in 2014. Non-inferiority of WATCHMAN compared to warfarin was repeatedly demonstrated. In addition, superiority for the primary efficacy endpoint (composite of stroke, cardiovascular death and systemic embolism) was seen for the first time. Also, the primary safety endpoint was similar to the warfarin group. The device group had a lower rate of hemorrhagic strokes in addition to a lower mortality rate with a 34 % relative risk reduction compared to warfarin.32 The results of the PROTECT AF and PREVAIL trials, in combination with the CAP registry and long-term follow up data from PROTECT AF, led to FDA approval of WATCHMAN in March 2015, in higher-risk patients (CHADS-VASc score of >2) with non-valvular AF as an alternative to long-term anticoagulation.

One of the major limitations to WATCHMAN is the necessity for anticoagulation for at least the first 45 days post-implant. This is a crucial consideration since one of the main indications for LAA occlusion is a contraindication to chronic oral anticoagulation. This prompted the ASA Plavix Feasibility Study with WATCHMAN Left Atrial Appendage Closure Technology (ASAP) study,33 which was a prospective, non-randomized study in patients who underwent WATCHMAN with a contraindication to oral anticoagulation. Instead of warfarin for the first 45 days, 150 patients with non-valvular AF and a mean CHADS2 score of 2.8 who underwent WATCHMAN received continuous aspirin and clopidogrel for six months. The primary efficacy endpoint was a composite of ischemic stroke, hemorrhagic stroke, systemic embolism and cardiovascular/ unexplained death, with a mean follow-up of 14 months. Serious procedure- or device-related safety events occurred in 8.7 % of patients.

All-cause stroke or systemic embolism occurred in four patients (2.3 % per year), ischemic stroke in three patients (1.7 % per year) and hemorrhagic stroke in one patient (0.6 % per year). The ischemic stroke rate was less than would be expected by CHADS2 score.33 This study suggested that LAA occlusion with WATCHMAN could be safely performed without a warfarin transition in patients with a contraindication to anticoagulation. These results must be interpreted with caution, however, since the study was small and observational in nature.

Another significant limitation to the WATCHMAN trials is that the device was compared only to warfarin. The novel oral anticoagulant medications are non-inferior, if not superior, to warfarin in efficacy and safety. The benefit of LAA occlusion with the rising use of NOACs for stroke risk reduction of non-valvular AF is unclear.

The Amplatzer™ Cardiac Plug (ACP) (St Jude) is another potential option for LAA occlusion. It was originally used for closure of a patent foramen ovale or atrial septal defect. The device was redesigned and used for the LAA. The first generation is a self-expanding nitinol wire mesh and polyester patch with a lobe and disk connected by a central waist. The device is delivered across a transseptal puncture into the LAA, and the disk unfolds to cover the appendage. There have been several small clinical studies showing successful LAA occlusion in approximately 98 % of the patients with risks of procedural complications in approximately 9.8 % of the patients.34 This device has been implanted under local anaesthesia as well as under general anaesthesia and post-procedure anticoagulation is not required. However, despite dual antiplatelet therapy post-procedure follow-up imaging detected thrombus formation on the device in 17 % of the patients. Other complications included stroke, major bleeding, pericardial effusion and device embolization. A second-generation device (ACP2 Amulet) has been developed that allows closure of larger LAA, improves stability, decreases the risk for embolization and is repositionable.35 This device is not currently available in the US.

Several other LAA occlusion devices such as WaveCrest™ (Coherex Medical), LAmbre™ (Lifetech), and CellAegis Devices are in development and early stages of testing.36 There are limited clinical safety and efficacy data on these so far but studies are ongoing. LAA occlusion represents a growing therapy for thromboembolic stroke risk reduction in patients with non-valvular AF, particularly in those who are unable to take long-term anticoagulation. More prospective trials with longer follow-up durations are needed in addition to comparisons against novel oral anticoagulants.

Transient Anticoagulation at the Time of Atrial Fibrillation Detection

In patients with whom rhythm control strategy is the preferred therapeutic option the duration of AF may play a critical role in determining the period of their most significant thromboembolic risk. Patients with AF lasting two days or more have a 5–7 % risk for clinical thromboembolism if cardioversion is not preceded by several weeks of warfarin therapy.37–40 The risk decreases to 0–1.6 % with 2–4 weeks of warfarin prophylaxis or short term anticoagulation therapy in addition to screening with tranesophageal echocardiogram.37,39 Hence, in patients with AF duration less than 48 hours, the benefit of thromobembolic risk reduction by anticoagulation warrants a closer examination to determine if these patients with short AF episodes require any anticoagulation therapy.

A prospective observational study attempted to estimate the thromboembolic risk of patients with AF duration less than 48 hours.41 A cohort of 357 patients admitted to a hospital with AF duration less than 48 hours were followed. One hundred and eighty-one patients (48.3 %) had a prior history of AF, and 23 (6.1 %) had a prior history of thromboembolism. Three hundred and fifty seven patients (95.2 %) converted to sinus rhythm during the index admission. Spontaneous conversion occurred in 250 patients (66.7 %) and pharmacological or electrical cardioversion was done in one hundred and seven patients (28.5 %). Three patients (0.8 %) who had converted spontaneously had a clinical thromboembolic event. One patient had a stroke, one had a TIA and one had a peripheral thromboembolus. None of the three patients had a prior history of AF or thromboembolism and all had normal left ventricular systolic function.

It was concluded that in patients presenting with AF duration less than 48 hours,the likelihood of cardioversion-related clinicalthromboembolism was low. A review of the published data,42 mainly from emergency medical patient encounters, supports the practice of cardioversion and discharge from the emergency room as safe and adequate rhythm control management for patients presenting with recent onset AF of less than 48 hours. The 2014 AHA/ACC/HRS AF guidelines16 assigns a Class IIb indication for cardioversion of patients with AF or atrial flutter of less than 48 hours duration, who are at low thromboembolic risk without the need for post cardioversion oral anticoagulation.

Pacemakers and cardiac defibrillators function as implanted cardiac rhythm monitors (ICMs) that provide a unique window on the occurrence of AF episodes. A targeted approach is to anticoagulate patients with ICMs during their most vulnerable period for thromboembolic risk during AF episodes may be an alternative therapy. This could potentially reduce chronic anticoagulation use, thereby reducing cost, bleeding risks and improving quality of life. The general approach of chronic anticoagulation in AF patients may be partly due to limitations in the ability to immediately and precisely respond to AF episodes when they occur. Hence, in patients with non-valvular, paroxysmal AF with brief episodes and who may otherwise be asymptomatic, the risk of bleeding from chronic anticoagulation may not be warranted. An alternative anticoagulation strategy may be supported by evidence for a temporal relationship between subclinical AF and embolic events.

The Asymptomatic Stroke and Atrial Fibrillation Evaluation in Pacemaker Patients (ASSERT) trial43 followed a cohort of 2,580 patients who had ICMs and no history of AF. During follow-up, 51 patients experienced stroke or systemic embolism. Of the 51 patients 51 % had subclinical AF (SCAF) recorded by their devices. In 18 patients (35 %) SCAF was detected before stroke or systemic embolism. However, only four patients (8 %) had SCAF within 30 days of the thromboembolic event. In patients with SCAF detected greater than 30 days before their thromboembolic event, the most recent AF episode to the time of the thromboembolic event had a median interval of 339 days. The authors inferred that, although there is an increased risk of thromboembolic events in patients with SCAF, very few had SCAF in the month before the events. Hence, with remote monitoring technology and real-time monitoring for the development of AF provided by ICMs, a new approach for targeted anticoagulation therapy may be considered in low-risk, low- burden and asymptomatic non-valvular AF patients.

The Rhythm Evalution for Anticoagulation with Continuous monitoring Trial (REACT.COM)44 is a pilot study that has been recently completed. It is designed as a single-arm, prospective multicenter study to test this strategy. The primary goal of the study was to reduce the duration of chronic anticoagulation therapy in addition to reducing the risk of stroke and bleeding with the use of ICM-guided novel oral anticoagulant (NOAC) therapy in response to specific AF episodes. Sixty-nine patients with nonpermanent AF were enrolled. Patients were initially monitored for 60 days to document that no AF episodes longer than one hour were recorded. NOACs were subsequently discontinued but reinitiated for a 30-day duration in response to an AF episode longer than one hour diagnosed through daily ICM transmissions. Over a mean follow-up of 466 ± 131 days, compliance with transmission was 98.7 %. AF episodes longer than one hour were noted in 18 (31 %) patients, resulting in a total time on NOAC of 1,472 days. The authors concluded that there was a 94 % reduction in the duration of NOAC therapy compared to chronic anticoagulation. There were three traumatic bleeding events in patients on aspirin, and three possible TIAs were observed in patients on aspirin with CHADS2 score of one. No strokes or death were noted over the study duration. This study demonstrated the feasibility of a tailored anticoagulation therapy for AF patients with the use of constant monitoring and rapid initiation of treatment to limit total anticoagulation therapy time significantly. While a larger study is necessary to validate the findings of this study, it demonstrates a potential opportunity for individualised management of anticoagulation therapy while potentially decreasing bleeding risks associated with chronic anticoagulation.

Conclusion

Stroke due to thromboembolism is a primary concern for patients with AF. Stroke prevention by systemic anticoagulation with an oral anticoagulant remains the standard of care for management of this risk. The newer CHADS2-VASc thromboembolic risk estimation tool has shifted the indications for chronic anticoagulation to include a significantly greater proportion of the AF patient population. The new NOAC agents appear superior to warfarin in terms of ease of use and lower risk of intracranial bleeding. Pooled data from major clinical trials of the NOACs suggest a superior protection against stroke relative to warfarin. Despite this, a significant fraction of the AF patient population has contraindications for chronic anticoagulation. In that group, the development of strategies for occlusion of the LAA has emerged as a viable therapeutic alternative. At present, data do not support rhythm control as a means for reducing thromboembolic risk.

References

  1. Manning WJ, Silverman DI, Keighley CS, et al. Transesophageal echo (TEE) facilitated early cardioversion for patients with new atrial fibrillation: a 4-year experience. Circulation 1994; 90 :1–21a.
  2. Stoddard MF, Dawkins PR, Prince CR, et al. Left atrial appendage thrombus is not uncommon in patients with acute atrial fibrillation and a recent embolic event: A transesophageal echocardiographic study. J Am Coll Cardiol 1995; 25 :452–9.
    Crossref | PubMed
  3. Stoddard MF, Singh P, Dawn B, et al. Left atrial thrombus predictes transient ischemic attack in patients with atrial fibrillation. Am Heart J 2003; 145 :676–82.
    Crossref | PubMed
  4. Atrial Fibrillation Investigators. Risk factors for stroke and efficacy of antithrombotic therapy in atrial fibrillation. Analysis of pooled data from five randomized controlled trials. Arch Intern Med 1994; 154 :1449–57.
    Crossref | PubMed
  5. The Stroke Prevention Investigators. Bleeding during antithrombotic therapy in patients with atrial fibrillation. Arch Intern Med 1996; 156 :409–16.
    Crossref | PubMed
  6. Fang MC, Go AS, Chang Y, et al. Predictors of warfarin discontinuation in older patients with atrial fibrillation. J Am Coll Cardiol 2008; 51 :A238.
    PubMed
  7. Ruff CT, Giuliano, Braunwald E, et al. Comparison of the efficacy and safety of new oral anticoagulants with warfarin in patients with atrial fibrillation: a meta-analysis of randomized trials. Lancet 2014; 383 :955–62.
    Crossref | PubMed
  8. Lip GY, Nieuwlaat R, Pisters R, et al. Refining clinical risk stratification for predicting stroke and thromboembolism in atrial fibrillation using a novel risk actor-based approach: the Euro Heart Survey on Atrial Fibrillation. Chest 2010; 137 :263–72.
    Crossref | PubMed
  9. Wyse DG, Waldo AL, DiMarco JP, et al. A comparison of rate control and rhythm control in patients with atrial fibrillation. N Engl J Med 2002; 347 :1825.
    Crossref | PubMed
  10. Van Gelder IC, Hagens VE, Bosker HA, et al. A comparison of rate control and rhythm control in patients with recurrent persistent atrial fibrillation. N Engl J Med 2002; 347 :1834.
    Crossref | PubMed
  11. Hohnloser SH, Kuck KH, Lilienthal J. Rhythm or rate control in atrial fibrillation--Pharmacological Intervention in Atrial Fibrillation (PIAF): a randomised trial. Lancet 2000; 356 :1789.
    Crossref | PubMed
  12. Carlsson J, Miketic S, Windeler J, et al. Randomized trial of rate- control versus rhythm-control in persistent atrial fibrillation: the Strategies of Treatment of Atrial Fibrillation (STAF) study. J Am Coll Cardiol 2003; 41 :1690.
    Crossref | PubMed
  13. Opolski G, Torbicki A, Kosior DA, et al. Rate control vs rhythm control in patients with nonvalvular persistent atrial fibrillation: the results of the Polish How to Treat Chronic Atrial Fibrillation (HOT CAFE) Study. Chest 2004; 126 :476.
    Crossref | PubMed
  14. Curtis AB, Gersh BJ, Corley SD, et al. Clinical factors that influence response to treatment strategies in atrial fibrillation: the Atrial Fibrillation Follow-up Investigation of Rhythm Management (AFFIRM) study. Am Heart J 2005; 149 :645.
    Crossref | PubMed
  15. Bahnson TD, Grant AO. To be or not to be in normal sinus rhythm: what do we really know? Ann Intern Med 2004; 141 :727.
    Crossref | PubMed
  16. January CT, Wann LS, Alpert JS, et al. 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. Circulation 2014; 130 :2071.
    Crossref | PubMed
  17. Bertaglia E, Stabile G, Pappone A, et al., Updated National Multicenter Registry on Procedural Safety of Catheter Ablation for Atrial Fibrillation. J Cardiovasc Electrophysiol 2013; 24 :1069–74.
    Crossref | PubMed
  18. Nair GM1, Nery PB, Diwakaramenon S, et al. A systematic review of randomized trials comparing radiofrequency ablation with antiarrhythmic medications in patients with atrial fibrillation. J Cardiovasc Electrophysiol 2009; 20 :138–44.
    Crossref | PubMed
  19. Blackshear JL, Odell JA. Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation. Ann Thorac Surg 1996; 61 :755–9.
    Crossref | PubMed
  20. Veinot JP, Harrity PJ, Gentile F, et al. Anatomy of the normal left atrial appendage: a quantitative study of age-related changes in 500 autopsy hearts: implications for echocardiographic examination. Circulation 1997; 96 :3112–5.
    Crossref | PubMed
  21. Inoue S, Murakami Y, Sano K, et al. Atrium as a source of brain natriuretic polypeptide in patients with atrial fibrillation. J Card Fail 2000; 6 :92–6.
    Crossref | PubMed
  22. Hoit BD, Shao Y, Gabel M. Influence of acutely altered loading conditions on left atrial appendage flow velocities. J Am Coll Cardiol 1994; 24 :1117–23.
    Crossref | PubMed
  23. Hoit BD, Shao Y, Gabel M. Influence of acutely altered loading conditions on left atrial appendage flow velocities. J Am Coll Cardiol 1994; 24 :1117–23.
    Crossref | PubMed
  24. Blackshear JL, Johnson WD, Odell JA, et al. Thoracoscopic extracardiac obliteration of the left atrial appendage for stroke risk reduction in atrial fibrillation. J Am Coll Cardiol 2003; 42 :1249–52.
    Crossref | PubMed
  25. Miller MA, Gangireddy SR, Doshi SK, et al. A Multi-Center Study on Acute and Long-Term Safety and Efficacy of Percutaneous Left Atrial Appendage Closure using an Epicardial Suture Snaring Device. Heart Rhythm 2014; 11 :1853–9.
    Crossref | PubMed
  26. Price MJ, Gibson DN, Yakubov SJ, et al. Early safety and efficacy of percutaneous left atrial appendage suture ligation: results from the U.S. transcatheter LAA ligation consortium. J Am Coll Cardiol 2014; 64 :565–72.
    Crossref | PubMed
  27. Di BiaseL,Burkhardt JD,Gibson DN, etal. 2Dand3D TEE evaluation of an early reopening of the LARIAT epicardial left atrial appendage closure device. Heart Rhythm 2014; 11 :1087–8.
    Crossref | PubMed
  28. Giedrimas E, Lin AC, Knight BP. Left atrial thrombus after appendage closure using LARIAT. Circ Arrhythm Electrophysiol 2013; 6 :e52–3.
    Crossref | PubMed
  29. Holmes DR, Reddy VY, Turi ZG, et al. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomized non- inferiority trial. Lancet 2009; 374 :534–42.
    Crossref | PubMed
  30. Holmes DR Jr, Kar S, Price MJ, et al. Prospective randomized evaluation of the WATCHMAN left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial. J Am Coll Cardiol 2014; 64 :1–12.
    Crossref | PubMed
  31. Reddy VY, Holmes D, Doshi SK, et al. Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECTAF) clinical trial and the Continued Access Registry. Circulation 2011; 123 :417–24.
    Crossref | PubMed
  32. Reddy VY, Sievert H, Halperin J, et al. Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial. J Am Med Assoc 2014; 312 :1988–98.
    Crossref | PubMed
  33. Reddy VY, Möbius-Winkler S, Miller MA, et al. Left atrial appendage closure with the Watchman device in patients with a contraindication for oral anticoagulation: the ASAP study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology). J Am Coll Cardiol 2013; 61 :2551–6.
    Crossref | PubMed
  34. Nietlispach F, Gloekler S, Krause R, et al. Amplatzer left atrial appendage occlusion: single center10-year experience. Catheter Cardiovasc Interv 2013; 82 :283–9.
    Crossref | PubMed
  35. Freixa X, Chan JL, Tzikas A, et al. The Amplatzer Cardiac Plug 2 for left atrial appendage occlusion: novel features and first-in- man experience. EuroIntervention 2013; 8 :1094–8.
    Crossref | PubMed
  36. Romero J, Natale A, Engstrom K, Di Biase L. Left atrial appendage isolation using percutaneous (endocardial/ epicardial) devices: Pre-clinical and clinical experience. Trends Cardiovasc Med 2016; 26 :182–99. Epub 2015 Jun 4;
    Crossref | PubMed
  37. Bjerkelund CJ, Orning OM. The efficacy of anticoagulant therapy in preventing embolism related to D.C. electrical conversion of atrial fibrillation. Am J Cardiol 1969; 23 :208–16.
    Crossref | PubMed
  38. Lown B, Perlroth MG, Kaidbey S, et al. “Cardioversion” of atrial fibrillation: a report on the treatment of 65 episodes in 50 patients. N Engl J Med 1963; 269 :325–31;
    Crossref | PubMed
  39. Weinberg DM, Mancini J. Anticoagulation for cardioversion of atrial fibrillation. Am J Cardiol 1989; 63 :745–6;
    Crossref | PubMed
  40. Peterson P, Godtfredsen J. Embolic complications in paroxysmal atrial fibrillation. Stroke 1986; 17 :622–6.
    Crossref | PubMed
  41. Weigner MJ, Caulfield TA, Danias PG, et al. Risk for clinical thromboembolism associated with conversion to sinus rhythm in patients with atrial fibrillation lasting less than 48 hours. Ann Intern Med 1997; 126 :615–20.
    Crossref | PubMed
  42. Von Besser K, Mills AM. Is discharge to home after emergency department cardioversion safe for the treatment of recent- onset atrial fibrillation? Ann Emerg Med 2011; 58 :517–20.
    Crossref | PubMed
  43. Brambatti M, Connolly SJ, Gold MR, et al. ASSERT Investigators: Temporal relationship between subclinical atrial fibrillation and embolic events. Circulation 2014; 129 :2094–9.
    Crossref | PubMed
  44. Passman, R, Leong-Sit P, Andrei AC, et al. Targeted Anticoagulation for Atrial Fibrillation Guided by Continuous Rhythm Assessment With an Insertable Cardiac Monitor: The Rhythm Evaluation for Anticoagulation With Continuous Monitoring (REACT.COM) Pilot Study. J Cardiovasc Electrophysiol 2015 Oct 29. [epub ahead of press]
    Crossref | PubMed